Fix and simplify CallOp/CallIndirectOp to LLVM::CallOp conversion
A recent ABI compatibility change affected the conversion from standard CallOp/CallIndirectOp to LLVM::CallOp by changing its signature. In order to analyze the signature, the code was looking up the callee symbol in the module. This is incorrect since, during the conversion, the module may contain both the original and the converted function op that have the same symbol name. There is no strict guarantee on which of the two symbols will be found by the lookup. The conversion was not failing because the type legalizer converts the LLVM types to themselves making the original and the converted function signatures ultimately produce the same type. Instead of looking up the function signature to get the list of result types, use the types of the CallOp/CallIndirectOp results which must match those of the function in valid IR. These types are guaranteed to be the original, unconverted types when converting the operation. Furthermore, this avoids the need to perform a lookup of a symbol name in the module which may be expensive. Finally, propagate attributes as-is from the original op to the converted op since they share the attribute name for the callee of direct calls and the rest of attributes are not affected by the conversion. This removes the need for additional contorsions between direct and indirect calls to extract the name of the optional callee attribute only to insert it back. This also prevents the conversion from unintentionally dropping the other attributes of the op. PiperOrigin-RevId: 272218871